All Products
-
High Voltage Ceramic Capacitor
-
High Voltage Doorknob Capacitors
-
High Voltage Film Capacitor
-
Live Line Capacitors
-
Surge Protective Device
-
High Voltage Vacuum Circuit Breaker
-
Switchgear Temperature Sensor
-
Voltage Instrument Transformers
-
Capacitive Voltage Detector
-
Capacitive Voltage Divider
-
Capacitive Insulator
-
MOV Metal Oxide Varistor
-
PTC NTC Thermistor
-
High Voltage Resistors
-
Richard“XIWUER is very innovative. They have provided excellent, intuitive service, looking ahead into the future as to what we might need.”
-
Mike"XIWUER's dedication to designing different specifications to meet our stringent processing requirements is a testament to our years of research and development."
-
Marry"XIWUER has impressive research capabilities and demonstrates good prototyping capabilities and high product quality."
Contact Person :
Wang Hong
Keywords [ high voltage ceramic capacitor ] match 639 products.
Voltage Transformer Secondary Grounding Surge Protective Device F-MS25-PVT/FM
Arrester Rated Voltage: | 260VAC |
---|---|
Ures: | ≤1000V |
Protection Level Up With In: | ≤2500V |
20kV Voltage Instrument Transformers Flange Type Transformer Bushings BLF-12-100
Current: | 100A |
---|---|
Rated Voltage: | 20kV |
Ambient Temperature: | -45℃~55℃ |
Low Voltage Polymeric Zinc Oxide Arrester Distribution Lightning Surge Arrester
Rated Voltage(kV): | 0.5kV |
---|---|
Maximum Operating Voltage: | 0.42kV |
Nominal Discharge Current (kA): | 1.5kA |
Voltage Divider Epoxy Resin Sensor Capacitive Post Insulator For Switchgear
Rated Voltage: | 20kV |
---|---|
Capacitance: | 390pF |
Temp. Char.: | 2B4 |
1200V 250A Vacuum interrupter for outdoor vacuum circuit breaker high voltage circuit breakers
Rated Voltage : | 1200V |
---|---|
Rated Current: | 250A |
Rated Short-time Power Frequency Withstand Voltage (1 Min): | 10KV |
Primary and secondary fusion electromagnetic combination AC voltage sensor high accuracy used for energy measurement
Rated Insulation Level: | 12/42/75kV |
---|---|
Rated Current Ratio: | Phase Sequence 1VA Zero Sequence: 0.5VA |
Current Accuracy Level (phase Measurement): | 5P10 (0.5S) Zero Sequence Protection 10P5 |
Epoxy Solid-sealed Pole Electronic Integrated Voltage Sensor Environmentally Friendly Outdoor Vacuum Circuit Breaker
Rated Voltage Ratio (phase Voltage: | 10 KV1√3|3.25|√3 |
---|---|
Rated Current Ratio (phase Current): | 600A/1V |
Rated Frequency: | 10 KV |√3/6.5/3 |
15.5kV High Voltage AC Automatic Recloser Used In 13.8kV Medium Voltage Overhead Line Power Grid
Rated Voltage: | 15.5KV |
---|---|
Rated Current: | 630A |
Rated Frequency: | 60Hz |
SM25-M6 Low Voltage Insulator High Strength Standoff Insulator Enhanced Performance for Demanding Applications
Thread: | M6 |
---|---|
Voltage Withstand: | 6KV |
Tensile Strength: | 300 |
Parallel Line PTC NTC Thermistor NTC Temperature Sensor drop type High Precision Thermistor
R25℃: | 2.75KΩ±3.8% |
---|---|
B0/25: | 3854± 1.5% |
Insulation Resistance: | ≥100 |